Auralex ELiTE Series: Installation Guide1
Auralex Tips Guide: Impaling Clips

ELiTET ProPanelT
Installation Guide

Impaling Clips
General guidelines for all panels:

1. Whenever moving panels, transport them with the shortest dimension in the vertical position to reduce potential stress or breaking of the fiberglass. Do not move panels parallel to the floor without additional support.

2. If light colored fabrics are used, it may be a good idea to wear white cotton gloves so dirt, grease or grime from the skin is not transferred to the fabric.

3. Lay out panels with a laser level (preferred), hand level or chalk line to ensure uniform installation. If panels are being placed directly up against one another, use the first panel as a reference point for adjoining panels to be installed.

4. Make sure the wall has a completely flat surface to install the panels to. Shim the panels if necessary to create a uniform front surface.

Installation using Impaling Clips
1. Mark the intended location of each panel on the wall.

2. Fasten impaling clips to the wall using drywall screws, concrete anchors or shots and pins for concrete block or pre–cast concrete walls using the guide below. Place the impaling clips 4” from the intended edge location and spread them evenly across the panel. (see Figure 1.2 and Figure 1.3)
Panel Size (1” or 2” thick) Number of Clips

NOTE: Panels over 2” thick must also use adhesives for installation.
2’x4’ 4
4’x4’ 4
4’x6’ 6
4’x8’ 6
4’x10’ 8

3. Start the panel ¾” higher than the intended wall location and press downward at a 45° angle toward the wall.
(see Figure 1.1)

4. Shim the clips as necessary to ensure the front edge of the panel is flush with adjoining panels.

5. Do not apply excessive pressure to a single or multiple small locations on the panel so as to crush or dent the fiberglass core.

6. This installation method will leave a ¾” reveal between the top of the panel and the ceiling.


Note on adhesives:
. The use of adhesives is highly suggested on all panel thicknesses for a secure permanent installation, though it is only mandatory for panels thicker than 2” or if they are being attached to the ceiling.

. Use ONLY water–based, heavy bodied adhesives, such as Auralex’s Tubetak Pro.

. Apply the adhesive liberally to the fiberglass and to the teeth of the impaling clip, but do not apply any adhesive within 3” from the edge of the panel.


CAV Recommended Products Click on this link for Auralex Products

About Contractor’s A/V.com

Contractor’s A/V.com is a resource for everyone (the public), from those new to technology through the most sophisticated professionals. CAV offers a one–stop resource to understand products and how to use them with a bias only for quality and value. Contractor’s A/V.com was created for this purpose since no other effective resource quite like it exists. Our objective is to help our customers make an informed purchase decision so as to get the most from their technology products and purchases.

Still Have Questions?

Feel free to e–mail us at techhelp@contractorsav.com or call us at  (888) 848–4228.

Contractor’s A/V.com – Technology Made Simple™

SHOPPING CART Shopping Cart
No items in cart.
Stay informed Privacy Policy
In-Wall and In-Ceiling Speakers